Code
Function
166
System
Management
175
System thermal Failed
180
Status display
201
System memory Failed
Table 14. Diagnostic error messages.
Result
Text message
Failed
ISMP Self Test Result failed test: x
(where x identifies part of the
subsystem experiencing problems, x
= [ROM, RAM, flash])
I2C Bus Error(s)
I2C cable is disconnected.
BIOS indicates ASM is unreachable.
Ensure ASM adapter is properly
seated in its supported slot.
Unable to communicate with ASM
adapter. It may be busy.
Communication with the ASM adapter
has failed.
ASM BIST indicate failed tests.
Unable to restart ASM adapter.
Fan # n
(where n is the number of the failing
fan)
Note: The fan LED on the diagnostic
LED panel will be lit.
Temperature sensed on processor
board is out of range
Failed
Diagnostic LED panel
Operator information panel
LED on hot-swap SCSI backplane
LED on system board
One or more fan LEDs are faulty.
DIMMs in location DIMM n
(where n is the number of the socket
that contains the failing DIMM)
Test setup error: Corrupt BIOS in
ROM
Test setup error: Corrupt DMI BIOS,
information in BIOS is not as expected
Action
Flash (or reflash) latest
firmware levels. Call for service.
If an system management
adapter is installed, reconnect
I2C cable between system
management adapter and
system board. Call for service.
Reconnect I2C cable between
system management adapter
and system board. Call for
service if the problem persists.
Ensure the optional system
management adapter (IBM
Remote Supervisor Adapter), is
seated in PCI Slot 1 (J44).
Rerun the test. Call for service if
the problem persists.
Disconnect all external server
and option power cords from
server, wait 30 seconds,
reconnect, and retry. Call for
service if the problem persists.
Replace the indicated fan.
If one of the fan LEDs on the
diagnostic LED panel is on,
replace the indicated fan. If the
problem persists, call for
service.
Call for service.
Replace the faulty fan.
1. Reseat the failing DIMM.
2. If the problem remains,
replace the DIMM.
If the problem persists, call
for service.
If your server does not have the
latest level BIOS installed,
update the BIOS to the latest
level.
If the problem persists, call for
service.
Chapter 6. Solving problems