Features And Specifications - IBM eServer 342 xSeries User Reference Manual

Hide thumbs Also See for eServer 342 xSeries:
Table of Contents

Advertisement

Features and specifications

The following table provides a summary of the features and specifications for your
xSeries 342 server.
Microprocessor:
®
®
Intel
Pentium
III
256 or 512 KB Level-2 cache
Supports up to two
microprocessors
Memory:
Maximum: 4 GB
Type: ECC, SDRAM, PC133,
registered DIMMs
Four slots (two-way interleaved)
Drives standard:
Diskette: 1.44 MB
CD-ROM: 24X IDE
Expansion bays:
Hot-swap: Three slim high
Non-hot-swap: Two 5.25-inch,
replaceable with a three slim-high
hot-swap drive expansion option
PCI expansion slots:
One 33 MHz/32-bit
Two 33 MHz/64-bit
Two 66 MHz/64-bit
Hot-swap power supplies:
270 Watt (115-230 V ac)
Minimum: One
Maximum: Two - the second power
supply provides redundant power
Video:
S3 video controller
Compatible with SVGA and VGA
8 MB video memory
Table 1. Features and Specifications.
*KB equals approximately 1000 bytes. MB equals approximately 1000000 bytes. GB
equals approximately 1000000000 bytes.
2
IBM xSeries 342: User's Reference
Size (rack model 3U):
Height: 128 mm (5 in.)
Depth: 695 mm (27.3 in.)
Width: 440 mm (17.3 in.)
Weight: 21.3 to 29.5 Kg (47 to 65
lb) depending upon configuration
Integrated functions:
Dual channel Ultra160 SCSI
controller
One 10BASE-T, 100BASE-TX,
100BASE-FX, Intel Ethernet
controller with Alert on LAN
®
Wake on LAN
support
Two serial ports
Two Universal Serial Bus ports
Keyboard port
Mouse port
Video port
Integrated System Management
(ISM) Processor
— Two ISM (RJ-45) connectors
— One system management
Serial C port
Acoustical noise emissions:
Sound power, idling (open bay):
6.6 bel maximum
Sound power, operating: 6.8 bel
maximum
Sound pressure, operating: 53
dBa maximum
Redundant cooling:
Three hot-swap fans
Environment:
Air temperature:
— Server on: 10° to 35° C
(50° to 95° F). Altitude: 0 to
914 m (2998 ft)
— Server on: 10° to 32° C
(50° to 89.6° F). Altitude:
914 m (2998 ft) to 2133 m
(6998 ft)
— Server off: 10° to 43° C
(50° to 109.4° F).
Maximum altitude: 2133 m
(6998 ft)
and
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
Minimum configuration: 375 Btu
(110 watts)
Maximum configuration: 1300
Btu (380 watts)
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
Input kilovolt-amperes (kVA)
approximately:
— Minimum: 0.08 kVA (0.076
kW)

Advertisement

Table of Contents
loading

Table of Contents