3.5.2 Fixing Sleeve Unit
3.5.2.1 Preparation for Removing the Fixing Sleeve Unit
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Remove the fixing assembly. (page
Assembly]
3.5.2.2 Removing the Fixing Sleeve Unit
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Turn the gear [1] to the position [2] in the direction of the arrow.
2) Remove the screw [1].
3) Free the claw [1] and claw [2] in this order to detach the cover [3].
4) Detach the cover [1].
- 2 screws [2]
- 1 claw [3]
3-26
3-25)[Removing the Fixing
F-3-190
F-3-191
F-3-192
F-3-193
0014-8837
0013-9996
5) Detach the guide [1].
- 2 claws [2]
When detaching the guide, set the protective sheet [1] to the fixing sleeve to
prevent scratch.
6) Detach the cover [1].
- 1 claw [2]
F-3-194