Canon i-SENSYS LBP5300 Series Service Manual page 133

Hide thumbs Also See for i-SENSYS LBP5300 Series:
Table of Contents

Advertisement

Code
Description
0000
Description
When 3.5 sec passed after activation of ETB motor, the cycle of ETB motor
speed detection signal does not become its specified value.
Cause
Error in ETB motor, error in DC controller PCB.
0001
Description
After ETB motor speed detection signal became the specified value of the cycle,
it exceeds the specified cycle for 2 continuous sec or more.
Cause
Error in ETB motor, error in DC controller PCB.
0002
Description
When 2.5 sec passed after activation of the yellow drum motor, the cycle of
drum motor speed detection signal does not become its specified value.
Cause
Error in drum motor, error in DC controller PCB.
0003
Description
After the yellow drum motor speed detection signal became the specified value
of the cycle, it exceeds the specified cycle for 2 continuous sec or more.
Cause
Error in drum motor, error in DC controller PCB.
0004
Description
When 2.5 sec passed after activation of the magenta drum motor, the cycle of
drum motor speed detection signal does not become its specified value.
Cause
Error in drum motor, error in DC controller PCB.
0005
Description
After the magenta drum motor speed detection signal became the specified
value of the cycle, it exceeds the specified cycle for 2 continuous sec or more.
Cause
Error in drum motor, error in DC controller PCB.
0006
Description
When 2.5 sec passed after activation of the cyan drum motor, the cycle of the
drum motor speed detection signal does not become its specified value.
Cause
Error in drum motor, error in DC controller PCB.
0007
Description
After the cyan drum motor speed detection signal became the specified value of
the cycle, it exceeds the specified cycle for 2 continuous sec or more.
Cause
Error in drum motor, error in DC controller PCB.
0008
Description
When 2.5 sec passed after activation of the black drum motor, the cycle of the
drum motor speed detection signal does not become its specified value.
Cause
Error in drum motor, error in DC controller PCB.
0009
Description
After the black drum motor speed detection signal became the specified value
of the cycle, it exceeds the specified cycle for 2 continuous sec or more.
Cause
Error in drum motor, error in DC controller PCB.
E014
Error in activation of fixing motor
0000
Description
When 2.5 sec passed after activation of fixing motor, the cycle of the fixing
motor speed detection signal does not become its specified value.
Cause
Error in fixing motor, error in DC controller PCB.
0001
Description
After the fixing motor speed detection signal became the specified value of the
cycle, it exceeds the specified cycle for 2 continuous sec or more.
Cause
Error in fixing motor, error in DC controller PCB.
E020
Error in density sensor
0000
Description
Cannot receive enough light when detecting image density.
Cause
Dirt on density sensor, error in density sensor, error in DC controller PCB, error
in toner cartridge.
E024
Toner level sensor failure
Action
- Replacement of ETB motor
- Replacement of DC controller PCB
- Replacement of drum motor
- Replacement of DC controller PCB
- Replacement of fixing motor
- Replacement of DC controller PCB
- Replacement of ETB unit
- Error in high-voltage joint (Check high-voltage joint for each
color, and each joint to high-voltage PCB)
- Replacement of DC controller
- Replacement of toner cartridge
Chapter 5
5-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents