12) Place the right side of the host machine downward, move the base plate
[1] approx. 30 mm from the pick-up drive assembly [2].
13) Remove the pick-up drive assembly [1].
- 2 screws [2]
14) Detach the plate [1].
- 4 screws [2]
15) Remove the manual feed pick-up solenoid [1].
- 1 screw [2]
F-3-167
F-3-168
F-3-169
F-3-170

3.4.8 Manual Separation Pad

3.4.8.1 Preparation for Removing the Manual Feed
Separation Pad
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Remove the ETB unit. (page 3-15)[Removing the ETB Unit]

3.4.8.2 Removing the Manual Feed Separation Pad

/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Remove the manual feed separation pad [1].
- 1 screw [2]

3.4.9 Duplexing Reverse Motor

3.4.9.1 Preparation for Removing the Duplexing
Reversing Motor
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Detach the rear cover. (page 3-1)[Removing the Rear Cover]
2) Remove the fixing assembly. (page
Assembly]
3) Detach the upper cover. (page 3-2)[Removing the Upper Cover]
4) Detach the duplexing driver PCB. (page 3-10)[Removing the Duplexing
Driver PCB]

3.4.9.2 Removing the Duplexing Reversing Motor

/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Free the claw [1] of the bushing.
2) Turn the bushing [1] to pull it out in the direction of the arrow.
Chapter 3
F-3-171
F-3-172
3-25)[Removing the Fixing
F-3-173
0014-8835
0013-9993
0014-4840
0014-4846
3-23