Daikin FTX25JVEA9 Service Manual page 132

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

Si18-201
Determination of initial frequency for heating
Initial frequency FSR is determined based on the correction of outside air temperature (DOA)
and discharge pipe temperature (DO) in accordance with the above matrix.
FSR = KFIDO × (-5/128 × (DOA - 15°C) × FINI1+FINI1)
3/ KFIDO varies depending on discharge pipe temperature DO
When DO ≥ DOFINI (45°C): KFIDO = KFIDOH (128/128) --- Hot start
When DO < DOFINI (45°C): KFIDO = KFIDOL (179/128) --- Cold start
Main Functions
Hot start
Cold start
300%
250%
200%
150%
100%
50%
0%
-20
-15
-10
-5
0
Reference Outside Air
Temperature
15°C
Outside Air
Temperature
-15
-10
-5
0
5
10
15
20
25
Outside
10
15
20
air temperature
Hot Start
128/128
Hot Start
Cold Start
217.2%
303.7%
197.7%
276.4%
178.1%
249.1%
158.6%
221.8%
139.1%
194.5%
119.5%
167.2%
100.0%
139.8%
80.5%
112.5%
60.9%
85.2%
System control
25
30
(M1010)
Cold Start
179/128
119