Si18-201
Step
4
Disconnect the earth
wire.
Disconnect the brazed
5
section of the
motorized valve.
"
When replacing the
motorized valve, change
its strainer too.
"
The strainer is located in
the brazed section of the
pipe.
Removal Procedure
Procedure
Outdoor Unit
Points
Warning
If refrigerant gas leaks during
the job, ventilate the room.
(Bear in mind that if the
refrigerant gas is exposed to
open flames, noxious gas may
be generated.)
Caution
Be careful not to get yourself
burnt with the motorized valve,
pipes and other parts that are
heated by the gas welding rod
Caution
Do not allow flames of a gas
welding rod to affect the parts
around the motorized valve.
Place welding protective sheets
or iron plates around
333