Daikin FTX25JVEA9 Service Manual page 257

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

Troubleshooting - Split Type Indoor Unit
1.5.10
Signal Transmission Error (Between Indoor Unit and Remote
Controller)
U5
Remote
Controller
Display
Indoor Unit LED
A
Display
Note:
No LED Display on FTK(X)25/35 J Series.
Method of
The data received from the indoor unit in indoor unit-remote controller signal transmission is
checked whether it is normal.
Malfunction
Detection
Malfunction
When the data sent from the outdoor unit cannot be received normally, or when the content of
Decision
the data is abnormal.
Conditions
"
Supposed
"
Causes
"
"
244
5
3
B
Faulty outdoor unit PCB.
Faulty indoor unit PCB.
Faulty remote controller cable.
Faulty remote controller.
Si18-201