Si18-201
Fan Speed Changeover when Thermostat is OFF
By setting to "Set Fan Speed," you can switch the fan speed to the set fan speed when the
heating thermostat is OFF.
take the setup location into consideration.
Setting Table
Main/Sub Setting when Using 2 Remote Controllers
Set the switch on the remote controller's PC board.
Control by 2 Remote Controllers (controlling 1 indoor unit with 2 remote controllers)
"
(MAIN/SUB CHANGEOVER)
Procedure
1. Insert a " - " screwdriver into the recess between the upper and lower part of remote
Insert the screwdriver here and gently work off the upper part of remote controller.
2. Turm the
Operating Test
Since there is concern about draft if using "fan speed up when thermostat is OFF," you should
Mode No.
12(22)
When using 2 remote controllers, one of either the control panel or the separate remote
controller must be set to "MAIN" and the other to "SUB".
controller and, working from the 2 positions, pry off the upper part. (The remote controller PC
board is attached to the upper part of remote controller.)
MAIN/SUB CHANGEOVER SWITCH
boards to "S". (Leave the switch of the other remote controller set to "M".)
First Code No.
Second Code No.
3
on one of the two remote controller PC
Method of Field Set
Setting
01
LL Fan Speed
02
Set Fan Speed