Technical Specification - Stuart Turner Multistage CH 4-30 Installation, Operation & Maintenance Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

5 TECHNICAL SPECIFICATION

Pump Model
Guarantee
General
Approvals
Features
Pump type
Priming vent plug
Self priming
Mechanical seal
Noise
Materials
Pump Body
Impeller
Performance
Maximum head (closed valve)
Performance @ 50 l/min
Performance @ 100 l/min
Maximum flow
Minimum static inlet pressure
Maximum static inlet pressure
Maximum static outlet pressure
Maximum working pressure*
Maximum ambient air temperature
Min / Max water temperature**
Maximum Suction Lift***
Connections
Pump connections
Motor
Type
Duty rating
Power supply / phase / frequency
Electrical
Current (full load)
Power consumption
Fuse rating
Power cable (pre-wired)
Enclosure protection
Physical
Length
Width
Height (excluding hoses)
Weight (including fittings)
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note:
**Note:
*** With footvalve fitted.
Although these pumps are self priming we recommend a footvalve/strainer is
used if a suction lift is required.
5.11 Noise: The equivalent continuous A-weighted sound pressure level at a
distance of 1 metre from the pump does not exceed 70 dB(A).
The maximum pressure that can be applied to the pump under any installation conditions.
A stored water temperature of 60
requirements and will minimise deposition of scale in hard water areas.
CH 4-30
CH 4-40
60 Hz
60 Hz
46643
46644
Centrifugal multistage
EPDM / Carbon / Ceramic
67 dB(A)
68 dB(A)
Brass / stainless steel
27 metres
42 metres
25 metres
40 metres
16 metres
28 metres
147 l/min
163 l/min
0.05 bar (0.5 metres)
1.0 bar (10 metres)
1.2 bar (12 metres)
600 kPa (6 bar)
50
C
50
o
o
Min 4
G 1¼ female (inlet), G 1 female (outlet)
Induction, auto-reset thermal trip
Continuous (S1) @ 2.5 l/min and above
220 V a.c. / 1 / 60 Hz
5.1 Amps
7.7 Amps
1070 Watts
1654 Watts
13 Amps
360 mm
384 mm
155 mm
190 mm
9.6 Kg
10.1 Kg
C is considered sufficient to meet all normal
o
- 11 -
CH 4-50
60 Hz
46645
1 year
CE
ü
ü
69 dB(A)
Stainless steel
56 metres
53 metres
39 metres
157 l/min
900 kPa (9 bar)
C
55
C
o
C / Max 65
C
o
o
5 metres
10.2 Amps
2203 Watts
0.75 metres
IPX5
431 mm
187 mm
210 mm
15.4 Kg
CH 4-60
60 Hz
46646
70 dB(A)
74 metres
72 metres
54 metres
174 l/min
50
C
o
13.6 Amps
2921 Watts
16 Amps
456 mm
17.8 Kg

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Multistage CH 4-30 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents