Diagnostic LED's: SFS
SFS "on"
Heater starts and runs OK,
but temperature of exhaust
climbs to 204°–260°C in
3-5 minutes.
NO
Heater starts after several
tries, exhaust temperature
stays below 121.1 °C.
OR
Heater doesn't start at all
(exhaust stays cold).
Check pressure and volume
of fuel supply
OK
Disconnect the sensor and
check continuity across its
terminals. Resistance
should be 3.5-4.0
megaohms.
= open circuit;
0
= shorted.
Does sensor check OK?
YES
Check continuity in wiring
harness between Control
YES
Board and Probe.
Continuity OK?
NO
Check the J3 and J6
connectors for corrosion/
looseness on the male
pins.
YES
Clean/tighten pins as
needed.
DONE
Reset power to Heater
and retry. Heater should
fire.
Check Heat Exchanger
Coil for leaks, liming, soot,
or low flow.
YES
YES
Check Thermal
Regulator: Open at
48.9°C?
NO
Correct problem;
Heater should fire.
NO
YES
Check Thermal-Regulator:
Seats correctly?
NOT OK
Correct Fuel Supply, reset
Heater and retry. Heater
should fire correctly.
NO
NO
Replace Stack Flue Sensor
DONE
Reset power to Heater and
retry. Heater should fire.
NO
Repeat checks on fuel
supply, Thermal Regulator,
check for correct orifices,
etc.
YES
NO
Does the Digital
Temperature Display show
Error Code "E05" or "E06"?
NO
Section 5. Troubleshooting
NO
NO
Replace Heater
YES
(HD)
Membrane Pad.
Replace Heater
Control Board.
Reset power to Heater and
retry. Heater should fire.
Check Heat Exchanger Coil for
leaks, liming, soot, or low flow.
Replace Heater Control Board.
Reset power to Heater and
retry. Heater should fire.
NO
Replace Heater Membrane Pad.
(Basic)
Reset power to Heater and
retry. Heater should fire.