CONTROL PANEL INDEXING

On an outdoor shelter installation, the exhaust discharges into
a vent pipe. Orient the heater so that the vent pipe does not
interfere with adjustment of the operating controls. The control
panel located on the top panel can be rotated to any of the
three sides of the heater for easy access, see Figure 20.
1. Remove the bolts from the door panels. Remove both door
access panels.
2. Remove the four corner screws that secure the top panel.
Lift the top panel upward to remove the top panel.
3. Rotate the top panel to the desired position located at 90°
angles. Note that the control panel must NOT be located on
the side where the vent is located.
4. Replace the top panel down onto the side panels. Be sure
that there are no wires caught under the panel.
5. Secure the top panel using the four corner screws.
6. Reattach the door access panels.

FINAL INSTALLATION CHECK

After installation, the installer MUST test and check that the heater
is operating and functioning properly.
Some building codes require that the heater be anchored to the
equipment pad or platform to withstand high wind pressures created
during hurricanes. A Bolt Down Bracket Kit, P/N 460738, is available
with anchor clamps designed to hold the unit to the equipment pad in
high wind conditions, see Figure 21. Installation of the anchor clamps
are recommended in all installations.

ELECTRICAL CONNECTIONS

Electrical Rating 50 Hz 240 Volts AC, single phase
The heater is supplied with a 240V VAC, 10 AMP, 50 Hz power cord (AS/NZS 3112) approved
for outdoor use. The power cord wire is 3 x 16 AWG (3 x 10 mm2).
!
CAUTION
This heater is designed to operate at 240 VAC. It is not recommended to be connected
to OR operate on 208 VAC.
NOTE
• If any of the original wiring supplied with this heater must be replaced, installer must supply (No.
18 AWG, 600V, 105° C. U.L. approved AWM low energy stranded) copper wire or it's equivalent.
Top Panel
Door
Access Panel
Figure 20.
Figure 21.
Door
Access
Panel