Waterco Turbotemp 200HD Installation And Operation Manual page 20

240 vac natural gas/lp gas
Table of Contents

Advertisement

HEATER CLEARANCES — General Requirements
INDOOR INSTALLATION AND OUTDOOR SHELTER
The following clearances must be maintained from the nearest walls: (See Figure 12 and Figure
12a)
TOP .............................. 15 cm. (6 in)
EXHAUST SIDE ......... 15 cm (6 in.)
HEADER SIDE ........... 15 cm (6 in.)
DOOR PANELS* ........ 15 cm (6 in.)
Note (*) For service access it is advisable to allow for sufficient clearance on at least one
door panel. The heater is designed for installation on combustible flooring. For installation on
carpeting, the heater must be mounted on a metal or wood panel that extends at least three
inches (10cm) beyond the base of the heater. If the heater is installed in a closet or alcove,
the entire floor shall be covered by the panel. On an outdoor shelter installation, the exhaust
discharges into a vent pipe. Orient the heater so that the vent pipe does not interfere with
adjustment of the operating controls. The control panel located on the top panel can be rotated
to any of the three sides of the heater for easy access. However, the control panel must not be
located on the side where the vent is located.
(*) For service access, it is advisable to
allow for suf cient clearance on at
least one door panel.
15 cm*
(6 in)
Figure 12.
OUTSIDE VENT COVER REMOVAL
The heater is supplied from the factory with a built-in stackless outside vent for outdoor
installation. Remove the outside vent cover for outdoor shelter installation.
Vent Cap and
Riser Furnished
15 cm (6 in)
by Installer
15 cm* (6 in)
15 cm (6 in)
Wall Vent
15 cm (6 in)
Chimney or Gas Vent
Side
Heater
Figure 12a.
Outlet Air
Opening
Inlet Air
Opening