Turn star wheel clockwise to raise
pressure set point if pressure switch is more
than 1.2M (4 ft.) below water level
Turn star wheel counterclockwise to lower
pressure set point if pressure switch is more
than 1.5M (5 ft.) above water level
HIGH LIMITS
A "High Limit", is a safety device that opens the electrical circuit and shuts off the heater
based on a water temperature set point within the "High Limit Device". The Turbotemp series
of heaters contains two (2) high limit devices which are located on the main inlet /outlet header.
OPERATION OF IGNITION MODULE
The Ignition Module, (see Figure 31), is microprocessor
based and operates on 24VAC supplied by the
transformer. The control utilizes a microprocessor to
continually and safely monitor, analyze, and control
the proper operation of the gas flame holder. The
module with the presence of the flame sensor, using
flame rectification, allows the heater to operate.
A reference scale is on
the back of pressure switch
Flame Current
Check Point
Star Wheel
Figure 30.
Diagnostic LED
1 Flash - Lockout
2 Flashes - Air Flow Fault
4 Flashes - Erroneous Flame
Figure 31.