Corrosive Vapors And Possible Causes - Waterco Turbotemp 200HD Installation And Operation Manual

240 vac natural gas/lp gas
Table of Contents

Advertisement

NOTE
Each 90-degree elbow reduces the maximum horizontal PVC air intake duct run by 3.6
metres and each 45-degree elbow in the PVC air intake duct run reduces the maximum
run by 1.8 metres. See the Table 5 above for the maximum lengths using 90-degree
elbows.

Corrosive Vapors and Possible Causes

Area
Chlorinated swimming
pools and spas
New construction and
remodeling areas
Beauty parlors
Refrigeration plants or
various industrial finishing
and processing plants
Dry cleaning and laundry
areas
Likely Contaminants
Pool or spa cleaning chemicals. Acids,
such as hydrochloric or muriatic acid.
Glues and cements, construction
adhesives, paints, varnishes, and paint
and varnish strippers. Waxes and cleaners
containing calcium or sodium chloride.
Permanent wave solutions, bleaches,
aerosol cans containing
chlorocarbons or fluorocarbons.
Refrigerants, acids, glues and cements,
construction adhesives.
Bleaches, detergents, or laundry soaps
containing chlorine.
Waxes and cleaners containing chlorine,
calcium or sodium chloride.
!
CAUTION
Chemicals should not be
stored near the heater
installation. Combustion
air can be contaminated
by corrosive chemical
fumes which can void
the warranty.
Table 5.
Section 3. Installation