Temperature Setting / Maximum - Waterco Turbotemp 200HD Installation And Operation Manual

240 vac natural gas/lp gas
Table of Contents

Advertisement

TEMPERATURE SETTING
The heater comes factory set at 25.6° C (78° F). for the pool mode and 37.8° C (100° F). for the
spa mode. Using the up and down arrows, you can set the pool/spa thermostats to a minimum
temperature of 18.3° C (65° F.), or a maximum of 40° C (104° F). If you desire to heat only one
body of water, the thermostat is capable of an off mode. As an example, if you only wish to heat
the spa and not the pool, simply depress and hold the pool down arrow, and the thermostat will
lower its setting to 18.3° C (65° F.) then go to an off mode. See below to change the heater's
factory set temperature settings.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the door panels (see Figure
33).
2. Access the control panel board on the underside
of the top cover. Locate the yellow button on the
corner of the control board.
3. Push the Max. Temp. Set Point button on the
back of the control board (see Figure 34).
The following sequence should happen:
A. The unit turns on and the POOL ON light will
turn on.
B. Press the
TOP of the panel) to set maximum pool
temperature.
C. Wait up to 30 seconds; the POOL ON light
will turn off and the SPA ON light will turn on.
To override the time delay, push the Max.
Temp. Set Point button again.
D. Press the
on the control panel and set maximum spa
temperature to 40°C (104° F) or less.
E. Wait up to 30 seconds; the SPA ON light
will turn off and the unit will shut down.
To override the time delay, push the Max.
Temp. Set Point button again.
4. Reinstall the access door panels.
TEMP or
TEMP pad (on
TEMP or
TEMP button
Top Panel
Door
Access Panel
Door
Access
Panel
Figure 33.
Figure 34.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Turbotemp 400hdTurbotemp 300hd

Table of Contents