OPERATING THE CONTROL PANEL

The five operating switches are:
POOL ON
Press this button to govern heater
operation by the pool temperature
setting.
SPA ON
Press this button to govern heater
operation by the spa temperature
setting.
HEATER OFF
Press this button to switch off the heater.
TEMP
Press this button to raise the temperature setting.
TEMP
Press this button to lower the temperature setting.
To toggle the display between degrees Centigrade (°C) and degrees Fahrenheit (°F):
1. Turn the Operating Control OFF.
TEMP or
2. Press
(°C to °F or vice versa).
3. Turn the Operating Control ON.
TEMP or
When either the
the temperature setting. After five seconds, the display will return to the actual pool/spa
temperature.
In addition to the digital temperature display, there are five indicator lights:
The POOL ON light indicates that the pool water temperature is governing operation of the
heater.
The SPA ON light indicates that the spa water temperature is governing operation of the heater.
The HEATING light comes on and stays on when the burner is firing. This light should be on
whenever the burner is on. It blinks when the heater is calling for heat but not firing. If this light
is on but the burner fails to come on, one of the "service" lights should come on, indicating a
fault in the system.
The SERVICE SYSTEM light indicates that there is insufficient water flow to the heater. If the
pump is operating, this usually indicates that the filter and/or skimmers should be cleaned
(some filters may require back-washing). If the light remains on after the filter/skimmers have
been serviced, the system should be checked by a qualified service technician.
The SERVICE HEATER light indicates a fault in the heater or its controls. If this light comes on,
shut down the heater (See "TO TURN OFF GAS TO THE APPLIANCE" on page 36), and have a
qualified service technician check the system.
!
WARNING
Risk of explosion or fire causing burns or death if safety interlocks are disabled. DO
NOT attempt to operate heater when SERVICE HEATER light is on or if blower or burner will
not start. Instead, follow instructions under "To Switch Off Gas to the Appliance," and call a
qualified service technician to repair unit.
TEMP for 5 seconds. The display will flash once and change modes