HACCP logging
Power optimisation connection
The HACCP process data is continuously output
via the unit interface. For this, a PC/laptop and
the CombiLink
software are required. For further
®
explanations, please refer to the CombiLink
manual. In addition, the HACCP process data is
stored for a period of 10 days and can be output via
the unit interface as required.
Outputting stored process data:
1
2
HACCP
3
Interrupts the continuous outputting of process
data.
24.08.07
4
5
Start time (date/time)
01.09.07
6
7
End time (date/time)
Download
8
The following data is logged:
Data output every 60 sec (in ASCII format)
– Batch no.
®
– Time
– Cooking process name
– Pan / stock temperature
– Core temperature
– Temperature unit
– Change of cooking mode
– Connection of energy optimisation system.
09:15
Connection of an energy
optimisation system
12:00
If the power supply is interrupted by an energy
optimisation system, this will be indicated on the
display (manual mode only).
- 47 -