HP 3000 SERIES II System Service Manual page 28

Computer system
Table of Contents

Advertisement

System Service
OPERATOR ACTION/COMMENTS
Enter in decimal the DRT number of the timer (usually 3).
Press RETURN
Enter in decimal the maximum number of error messages
you wish to receive.
Press RETURN
Enter A
Press RETURN
Enter NO
Press RETURN
Enter tape model suffix designator B, or E, NO= no tape
unit present.
Press RETURN
Enter tape model suffix designator.
Press RETURN
Enter tape model suffix designator.
Press RETURN
Enter tape model suffix designator.
Press RETURN
Remove the stand alone diagnostic tape and mount a scratch
tape 80-100 feet long.
(This message is asking if you are satisfied that all previous
entries are correct before proceeding.)
Enter YES
Press RETURN
Set all bits of the SYSTEM SWITCH REGISTER off.
Press RETURN
Program executes and message appears on the console after
a complete pass (approximately 20 minutes for 100 feet of
tape). Program will repeat until HALT is pressed.
CONSOLE MESSAGE
Q012 MAXIMUM ERROR PRINT COUNT?
P005 TYPE FOLLOWING CONTROL
A'CR'-AUTO
E'CR'-EXIT
R'CR'-RESTART
M'CR'-MANU
'CR'-RESUME
YOUR CODE?
D015 PRESENT SECTION REGISTER:
%077414 DO YOU WISH TO CHANGE? (YES/NO)
Q019 AUTO-PRCESS: ENTER TAPE UNIT (B,E,NO) AT
Q020 DRIVE O?
Q020 DRIVE 1?
Q020 DRIVE 2?
Q020 DRIVE 3?
P003 UNLOAD PROGRAM TAPE -
LOAD TEST
TAPE(S)
Q030 ALL DEFINITIONS CORRECT (YES/NO)?
POll UPDATE SWITCH REGISTER (CR)
P060 01 PASS 000000 TOTAL ERRORS
1-24.
HP 30055A SYNCHRONOUS SINGLE LINE CONTROLLER (SSLC)
PCA DIAGNOSTIC (D434)
Prior to executing the diagnostic, the SSLC PCA interconnecting cable must be terminated with test
connector part number 30055-60005. The following procedure is used to verify operation.
1-18

Advertisement

Table of Contents
loading

Table of Contents