System Service
OPERATOR ACTION/COMMENTS
Press RUN (Time for one pass is approximately two
minutes.)
NOTE
The following console message appears if no
SCMB's are installed in the multiplexer
channel.
With one SCMB installed, message P18 is not displayed.
With both SCMB's installed, messages P18 and P19 are
supressed, and the following messages appear.
Program restarts and continues to run until operator presses
HALT switch.
CONSOLE MESSAGE
P02 END SECTION IORES
P02 END SECTION ARADDR
P02 END SECTION ARDATA
P02 END SECTION ARCPP
P02 END SECTION ORADDR
P02 END SECTION ORDATA
P02 END SECTION ORCP
P02 END SECTION AREG
P02 END SECTION OREG
P02 END SECTION NSGPI
P02 END SECTION NSGP2
P02 END SECTION NSGP3
P02 END SECTION NSGP4
P02 END SECTION STPAR
P18 1ST SCMB DRT# NOT ENTERED; STEPS 41-74
ABORTED
P19 2ND SCMB DRT# NOT ENTERED; STEPS 75-78
ABORTED
P16 FAST SR READ MODE (2K XFER); TIME = 4 MSEC.;
BANK 00; STEP 63
P16 FAST SR READ MODE (2K XFER); TIME = 4 MSEC.;
BANK 01; STEP 63
PI7 FAST SR WRITE MODE (2K XFER); TIME = 4
MSEC.; BANK 00; STEP 68
P17 FAST SR WRITE MODE (2K XFER); TIME = 4
MSEC.; BANK 01; STEP 68
P02 END SECTION SIOTST
D02 END MPX CHAN TEST
D03 END: PROGRAM CYCLE: PASS= 1
1.. 16.
HP 30102A DISC FILE DIAGNOSTIC
(D423)
The diagnostic verifies the input, output, and control functions of the HP 30102A Disc File. The
following procedure is used to verify operation.
NOTE
Prior to running this diagnostic a SYS DUMP should be per-
formed to save information stored on the disc pack. When answer-
ing the dialogue for the SYS DUMP, enter 0 for the date so that
all the data is saved.
1-10