HP 3000 SERIES II System Service Manual page 163

Computer system
Table of Contents

Advertisement

System Service
NOTE
SP1 is the first register tested and the problem may not necessarily be in
SP1 but somewhere previous in the data path (Store logic, Shifter,
ALU, etc.).
A-3.
MEMORY TEST
A memory configuration test is available from the microprogram for testing memory. Memory config-
uration test diagnostic time is approximately ten seconds.
To run the memory diagnostics, perform the following steps:
a. Set the SYSTEM SWITCH REGISTER to %000200.
b. Press the ENABLE and LOAD switches.
c.
Program runs until an error occurs.
When an error occurs the program pauses and the CIR contains the error data (lamp on
=
error bit). By
pressing the RUN/HALT switch, the CIR then contains the address information shown in table A-2.
The test should be continued so all memory is tested before any repairs are made. The test is
terminated by pressing the HALT switch.
Table A-2. CIR Address Information
CIR BIT
FUNCTION
0:3
Address bits 0:3
6,7
Bank number
10:14
CPX1 register bits 2:6
10
(2) Illegal address
11
(3) CPU timer
12
(4) System Parity Error
13
(5) Address Parity Error
14
(6) Data Parity Error
15
Address bit 15
A-4.
I/O TEST
A Test Input/Output (TIO) instruction is executed on each I/O device number (3 through %177) in
sequence. Only those device numbers with a device connected will respond; empty device numbers are
skipped. To run the I/O test, perform the following steps:
NOTE
If the HP 30354A Maintenance Panel is connected to the system,
the TIMERS switch must be set to ENABLE.
A-2