Acg Charge Performance; Check Circuits Of The Starter System - PGO Tigra AF-125BAE Service Manual

Table of Contents

Advertisement

ACG charge performance

 Use a clamp meter to test charge performance by turning the rotary switch to the "current" (and
"voltage") function; connect the fuse's "+" to measure current (and voltage) at charging.
RPM
1600
3000
4000
5000
6000
7000
3.
Starter system

Check circuits of the starter system

1.
Turn the main switch and press the brake lever to start the engine. Any "click" heard implies the start
relay normal.
2.
Disconnect the "+" terminal (Red) of the start relay, i.e., wiring connected to the starter.
3.
Turn a multi-meter's rotary switch to the "Ω" function and connect "+" of the multi-meter (Red) to
the motor.
4.
Turn the start switch and start the engine; check the multi-meter.
5.
Please change the start relay in the event of "OPEN" shown on the multi-meter.
6.
Check the start switch with a multi-meter by connecting Green/White (+) and Black (-) in the event of
the start relay normal.
Start relay
Day
Voltage
Current
14.45
0.94
14.47
0.95
14.48
0.86
14.48
0.87
14.48
0.86
14.49
0.85
Charge, Ignition, and Start-up 13
Night
Voltage
Current
13.23
0.5
14.16
1.45
14.18
1.35
14.18
1.27
14.20
1.14
14.20
1.15
Test the start switch with a multi-meter
90
Some errors are expectable for each
battery's distinct status.
The data shown in the table is derived
from a good battery.