Engine Oil Check - PGO Tigra AF-125BAE Service Manual

Table of Contents

Advertisement

3) Engine oil
Volume
Total oil volume: 1000c.c.
Oil volume replaced: 800c.c.
Service cycle: 1000km
Check the oil level
 Park the motorcycle on a horizontal surface for
check.
 Start the engine for 3-minute running and stop
it for another 3-minute; make a measurement.
1. Remove the oil meter counterclockwise and clean it.
2. Screw the oil meter into the filling orifice to measure
the oil level.
3. The oil level should be higher than the lower limit but
lower than the upper limit. Add any engine oil for oil
insufficient.
△Note: Some disadvantages such as engine damage and
performance deterioration may be attributed to engine
oil out of the range.
Oil replaced
1. Remove and clean the drain plug bolt; check the gasket for any
defect and replace the defective gasket with a new one. Screw
the bolt with the engine oil evacuated.
2. Remove and clean the oil meter. Add new engine oil to 800c.c.
(volume replaced) and screw the oil meter.
3. Start the engine and check any engine oil leaked; remove the
oil meter and check the oil level again.
Torque: 2.5~3.5(kg-m)
△ Note: Engine oil to be replaced shall be 1000c.c. for the
engine disassembled and installed.
Check & Adjustment
32
3
Upper limit
Lower limit

Hide quick links: