Command
/+[Y]/[X]:******.
34/52
Function
Set communication between PC and
HDBaseT receiver.
① Y is for RS232 port (connect with
RS232 port of HDBaseT receiver)
Y= 1~9 or A~P, The value of Y is
defined into the following meanings
(in a given baud rate depended by the
value of X):
a. Y = 1~8, send this command to the
corresponding HDBaseT receiver to
control far-end device.
b. Y = 9, send this command to all
HDBaseT receivers to control all
far-end devices.
c. Y = A, B, C, D, E, F, G or H
d. Y = I, J, K, L, M, N, O or P
For items c or d, send this command,
it will be saved to the matrix switcher
but taken without action to
corresponding HDBaseT receiver.
And its command function will be
effective almost at the same time
when you send the command PWON
(for item c) or PWOFF (for item d).
Note:
A & I are for port 1. B & J are for port
2.
C & K are for port 3. D & L are for
port 4.
E & L are for port 5. F & N are for
port 6.
G & O are for port 7. H & P are for
port 8.
② X is for bound rate, its value ranges
from 1 to 7 (1--2400, 2--4800,
3--9600, 4--19200, 5--38400,
6—57600, 7--115200)
③ ***** is for data (max 48 Byte)