8 Operation Details
8.1.
Heating Operation
• Heating operation can be set using remote control.
• This operation is applied to warm the room temperature reaches the setting temperature set on the remote control.
• The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
to 30°C.
• During heating operation, the compressor will stop running and restart as shown in below figure.
8.1.1.
Heating Operation Time Diagram
17
CS-A9DKA CU-A9DKA / CS-A12DKA CU-A12DKA /