Show Alarm Parameters - Alvarion BreezeAccess II System Manual

Hide thumbs Also See for BreezeAccess II:
Table of Contents

Advertisement

Menus and Parameters
Alarms Out Control
The Alarms Out Control menu allows the functionality of the Alarms Out
control mechanism to be defined. Its main purpose is to support
"manual" activation/deactivation of each of the Alarms Out either
locally or remotely using Telnet or SNMP. For each of the three Alarms
Out, the following control options are available:
! 0 – Turn Alarm OFF (even if it should be ON according to the
definition in the Automatic Alarms Out Definition Menu).
! 1 – Turn Alarm ON (even if it should be OFF according to the
definition in the Automatic Alarms Out Definition Menu).
! 2 – Automatic (activate/deactivate according to the definition in the
Automatic Alarms Out Definition Menu).
The default for all three Alarms Out is 2 (Automatic).

Show Alarm Parameters

Shows the current values of the Alarms In and Alarms Out parameters
as well as their current status:
! Alarms In Names And Status
Displays the names and current status (ON or OFF) for all Alarm In
indications, including "internal" alarms, as follows:
" Alarm In 1 through Alarm In 4: Name according to the name
defined in the Alarms In Names Menu.
" Alarm In 5: GPS Antenna Status.
" Alarm In 6: NA (reserved for future use).
" Alarm In 7: PS1 Over Temperature (over temperature indication
for BS-PS Power Supply module 1, which is the module inserted
in the left-most slot of the chassis).
" Alarm In 8: PS2 Over Temperature (over temperature indication
for BS-PS Power Supply module 2, which is the module inserted
in the right-most slot of the chassis).
" Alarm In 9: PS1 Power (power fail indication for BS-PS Power
Supply module 1, which is the module inserted in the left-most
slot of the chassis).
" Alarm In 10: PS2 Power (power fail indication for BS-PS Power
Supply module 2, which is the module inserted in the right-most
slot of the chassis).
NOTE:
In some installations only one Power Supply module (either PS1 or PS2) may
be used.
! Alarms Out Names, Definitions, Control and Status
Displays the following information for each of the three Alarms Out:
BreezeACCESS Version 4.5 System Manual