Alvarion BreezeAccess II System Manual page 160

Hide thumbs Also See for BreezeAccess II:
Table of Contents

Advertisement

2-30
High Retransmissions Rate Alarm
Severity:
On Conditions:
Off Conditions:
Possible Problem:
Manual Revision: 1.0
BreezeACCESS Version 4.5 Operations and Administration
Minor, Major
Minor Severity Alarm:
a. The Retransmissions Current Rate exceeds the
Retransmissions Minor Alarm Threshold, and is
higher than the Retransmissions Average Rate by at
least Retransmissions Minor Alarm Minimum Delta,
-OR-
b. The Retransmissions Current Rate has dropped below
the Retransmissions Major Alarm Threshold but is still
higher than the Retransmissions Minor Alarm
Threshold.
Major Severity Alarm: The Retransmissions Current Rate is
higher than the Retransmissions Major Alarm Threshold.
a. The Retransmissions Current Rate has dropped below
the Retransmissions Minor/Major Alarm Threshold,
-OR-
b. All alarms were cleared,
-OR-
c. AU Alarms Option was disabled
a. Transmitter or receiver fault
b. Poor link conditions, strong interference, or an
overloaded network.