Alvarion BreezeAccess II System Manual page 235

Hide thumbs Also See for BreezeAccess II:
Table of Contents

Advertisement

Menus and Parameters
an RCF containing the same timeToLive or a shorter
timeToLive. After this time, the registration will expire. The
timeToLive is expressed in seconds. Prior to the expiration
time, the endpoint may send an RRQ message with the
keepAlive bit set. The keep-alive RRQ resets the time to live
timer in the Gatekeeper, enabling the registration to be
extended. After the expiration time, the endpoint must
re-register with a Gatekeeper using a full RRQ message.
Valid values: 0 (the keep-alive mechanism is not activated),
1-65535 (seconds)
Default value: 0
" IRQ Polling - To enable or disable IRQ polling by the gatekeeper.
When enabled, the gatekeeper is responsible for sending
keep-alive messages to the SU. When disabled, the SU is
responsible for sending the keep-alive RRQ messages to the
gatekeeper.
The default selection is Disable.
! Dialing Options
" Pulse Dialing – Enables or disables the automatic pulse dialing
detection feature to support telephones with pulse dialing.
The default selection is Enable
" IP Dialing Option – Enables or disables dialing using IP
addresses.
The default selection is Enable.
" IP Dialing Indicator – Specifies the prefix used to identify an IP
Dialing string. Applicable only if the IP Dialing Option parameter
(see above) is set to Enable. Digits dialed after IP Dialing Prefix
are assumed to be the destination IP address. 12- and 3-digit
numbers are allowed. 3- digit numbers are used to dial to
stations in the same subnet, and 12- digit number are used to
dial to any IP address. If a 3-digit number is dialed the Setup
message is sent to the corresponding IP address in the local
subnet. When dialing a 12-digit number (e.g. abcdefghijkl), the
Setup message is sent directly to the IP address abc.def.ghi.jkl.
Valid values: up to 3 phone key-pad digits (0-9, *, #, A, B, C, D)
The default value is *.
" Stop Dialing Timeout: - The inactivity time following the last
dialed digit that will be identified by the unit as an indication to
end of dialing.
Valid range: 3 to 60 seconds
Default value: 5 seconds