Vacuum Pick Switch - Activates & deactivates vacuum pump supply to
the Vacuum Pick Assembly. Switch must be depressed for a period of
0.5 second before circuit deactivation; activation is immediate.
VACUUM PICK ADJUST CONTROL – Provides adjustment for
height of Vacuum Pick Assembly (& Vacuum Cup). Turn clockwise to
raise pick or counterclockwise to lower pick.
CYCLE SWITCH - Activates reflow cycle (heat & airflow). Switch
must be held to maintain activation in Manual Mode; in Timed &
Program Modes, switch is pressed & released to initiate set cycle
time. Switch can be used to abort cycle in Timed or Program
Mode operation.
HEAT SHIELD-Protects the operator from unintentional
contact with the heater.
QUICKFIT NOZZLE ADAPTER - Allows quick nozzle
attachment and release.
NOZZLE ASSEMBLY - Directs heated air from the heater
assembly to the solder joint areas for soldering or
desoldering of components. Nozzles are optional parts
ordered for a specific application.
VACUUM PICK ASSEMBLY - Provides a means to lift or
place components.
VACUUM CUP - Provides positive holding of components for positioning
during the replacement process and for lifting of the component during the
removal process.