IPAC Server Administrator's Manual
8. Under the Control Panel dropdown menu, select the control panel that
corresponds to your elevator.
9. Select the input.
10. Enter (in seconds) the amount of time for the device to pulse when provided
with a valid credential.
11. If you wish to require the display of two credentials in order to permit access,
enable a two-factor credential schedule from the dropdown list. If you do not
wish to require two-factor credentials, choose "none."
12. Enter (in seconds) the amount of time allowed before the option to display two
credentials expires.
13. If you wish to enable alarm console settings, check the "include failed access as
alarms" checkbox. You may also combine alarms, provide instruction text, set
alarm priority, schedule when the alarm will function, and whether or not an
elevator will function during certain threat levels.
14. If you wish to enable antipassback, check the enable box. You may also enable
soft reset with a given number of minutes and determine which antipassback
zones will be primary or alternative.
15. You may have the elevator ignore Threat Levels or select under what Threat
Level conditions the elevator will operate and if the elevator will require two
factor credentialing.
16. If you want to control access to a particular floor, match the relay to the
corresponding floor by selecting from the dropdown list.
17. If you wish to apply any Keypad Commands to this elevator, click on the
and select the Keypad Command from the popup window.
18. Click Save.
83
Page 83 of 334