Use the 8 mm socket wrench to loosen and remove the nuts (1).
Remove the actuator module together with the mounting plate (2).
If the actuator module is to be replaced:
Use the 7 mm socket wrench and a Phillips screwdriver to loosen and remove the nuts (3).
If the electronic module is to be replaced:
Remove the electronic module.
Replace the defective modules.
Installing electronic modules:
Install the various modules in reverse order.
Reconnect all cable connectors to their former positions.
If you have replaced ACS II electronic module, please select the correct drive program, as
described in chapter 8.2.4.
Update the drive program, in case a new software version is available, as described in chapter
8.3.
Modify the drive program using the programming software as needed.
The last step is to test all functions of the vehicle.