Method 2 - Power Supply Cord
Plug into a grounded 3 prong outlet.
Do not remove the ground prong from the power cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to do so can result in death, re or electrical shock.
IMPORTANT: The power cord and connections must comply with the National
Electrical Code, Section 422 and/or local codes and ordinances. Recommended cord
length is 54" min. and 64" max.
1. Confirm that power is turned off at the source.
2. Remove terminal box cover. Retain for later use.
3. Install a UL listed/CSA approved strain relief.
4. Route power cord so that it does not touch dishwasher motor or lower part of
dishwasher tub.
5. Pull power cord through strain relief in terminal box.
a
6. Connect the wires as follows using UL listed wire nuts of the appropriate size to
connect power cord to 16-gauge dishwasher wire.
WARNING
Electrical Shock Hazard
Power supply wire:
white
black
ground wire
a
Strain Relief
Terminal box wire:
white
black
ground connector