Baxi Solo 2 60 RS Installation And Servicing Instructions page 24

Wall mounted room sealed gas fired central heating boilers
Table of Contents

Advertisement

24
Loosen the securing screw sufficiently for the electrical
cover to be removed from the thermostat box.
75
br
g/y
b
bk
S/L N
P/L
L N
Pump
Fit the pump outlet as follows:
S/L N
secure the cable to the bottom of the combustion box.
In the event of an electrical fault after installation of the
appliance, preliminary electrical system checks should
be carried out:- earth continuity, polarity and resistance
to earth.
Bare back the input cable to the
dimensions shown.
35
Fit the electrical input cable as follows:
Connect the switched live to the terminal
marked S/L.
Connect the permanent live to the
terminal marked P/L.
Connect the supply neutral to the
terminal marked N and the supply earth
to the terminal marked
Secure the cable in place with the right
hand cable clamp.
Connect the pump earth to the
terminal marked
Connect the pump neutral
to the terminal marked N.
cable clamp.
P/L
L N
Replace the electrical cover
Pump
and securing screw.
A cable clip is supplied in the kit to
.
.
Connect the pump live
to the terminal marked
L.
Secure the cable in
place with the left hand