Flue Trim
16
Unpack flue duct, flue trim and air duct.
Flue Duct
Wall Thickness
For wall thickness between 102mm (4in) and 280mm
(11in), air duct and flue duct are required to be
shortened.
Using the indication on the duct, mark accordingly to
table below.
Flue Preparation
Air Duct
Measure overall wall thickness. If this is between
280mm (11in) and 355mm (14in), use flue as
supplied without alteration.
Cut off
3in
6in
7in
Bend tabs as shown.
Using tin snips, cut around ducts at appropriate
mark. Remove any sharp edges.
Wall Thickness
203mm - 280mm
(8in) - (11in)
127mm - 203mm
(5in) - (8in)
102mm - 127mm
(4in) - (5in)