Introduction - Baxi Solo 2 60 RS Installation And Servicing Instructions

Wall mounted room sealed gas fired central heating boilers
Table of Contents

Advertisement

"Benchmark" Log Book
As part of the industry-wide "Benchmark" initiative
all Baxi boilers now include an Installation,
Commissioning and Service Record Log Book.
Please read the Log Book carefully and complete
all sections relevant to the appliance and
installation. These include sections on the type of
controls employed, flushing the system, burner
operating pressure etc. The details of the Log
Book will be required in the event of any warranty
work. Also, there is a section to be completed at
each subsequent regular service visit.
B.S. Codes of Practice
STANDARD
BS 6891
BS 5546
BS 5449 Part 1
systems.
BS 6798
BS 5440 Part 1
BS 5440 Part 2
WARNING
The addition of anything that may interfere with the
normal operation of the appliance (e.g. FLUE
DAMPERS,ECONOMISERS etc) without the express
written permission of BAXI could invalidate the
appliance warranty and infringe the GAS SAFETY
(Installation and Use) REGULATIONS.
SCOPE
Gas Installation.
Installation of hot water supplies
for domestic purposes.
Forced circulation hot water
Installation of gas fired hot water
boilers.
Flues.
Air Supply.

INTRODUCTION

Description
The Baxi Solo 2 RS is a wall mounted gas
fired room sealed natural draught central
heating boiler with range rated outputs as
shown in the table below.
Model
Min
30
6.15kW (21,000 Btu/h)
40
9.09kW (31,000 Btu/h)
50
12.02kW (41,000 Btu/h) 14.65kW (50,000 Btu/h)
60
14.95kW (51,000 Btu/h) 17.58kW (60,000 Btu/h)
Each appliance is preset at its MAXIMUM
heat input rating and is designed for use on
NATURAL GAS only. They are suitable for
gravity domestic hot water with pumped
central heating, fully pumped open vented
central heating and domestic hot water and
sealed systems.
The standard flue assembly supplied is suitable
for wall thicknesses between 100mm (4in) and
356mm (14in). An optional flue extension kit is
available for walls of 356mm (14in) and 610mm (24in)
thickness.
The appliance data badge is fitted to the combustion
chamber door above the gas valve.
Installation
The installation must be carried out by a CORGI
Registered Installer and be in accordance with the
relevant requirements of GAS SAFETY (Installation
and Use) REGULATIONS, the BUILDING
REGULATIONS (Scotland) (Consolidation), the
LOCAL BUILDING REGULATIONS, the current I.E.E.
WIRING REGULATIONS and the bye laws of the
LOCAL WATER UNDERTAKING. (Where no specific
instruction is given reference should be made to the
relevant BRITISH STANDARD CODES OF
PRACTICE.)
Important Information
This product contains Refractory Ceramic Fibres (R.C.F.) which are
man-made vitreous silicate fibres. Excessive exposure to these
materials may cause temporary irritation to eyes, skin and respiratory
tract. Care must be taken when handling these articles to ensure the
release of dust or fibres is kept to a minimum. To ensure that the
release of fibres from these articles is kept to a minimum, during
installation and servicing it is recommended that a H.E.P.A. filtered
vacuum is used to remove any dust, soot or other debris
accumulated in and around the appliance. This should be performed
before and after working on the installation. It is recommended that
any replaced item(s) are not broken up but sealed within heavy duty
polythene bags and clearly labelled "R.C.F. waste". This is not
classified as "hazardous waste" and may be disposed of at a tipping
site licensed for the disposal of industrial waste. Protective clothing is
not required when handling these articles but it is recommended that
gloves are worn and the normal hygiene rules of not smoking, eating
or drinking in the work area are followed and always wash hands
before eating or drinking.
HEAT OUTPUT
Max
8.79kW (30,000 Btu/h)
11.72kW (40,000 Btu/h)