User's Operating Instructions &
Important Warranty Information
Megaflo System HE
Range
A
Gas Fired Wall Mounted Condensing Boiler
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
© Baxi Heating UK Ltd 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Megaflo System HE A Range and is the answer not in the manual?

Questions and answers

Summary of Contents for Baxi Megaflo System HE A Range

  • Page 1 User’s Operating Instructions & Important Warranty Information Megaflo System HE Range Gas Fired Wall Mounted Condensing Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2012...
  • Page 2: Table Of Contents

    Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk © Baxi Heating UK Ltd 2012 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any...
  • Page 3: Quick Reference Guide

    Central Heating System Pressure - The normal operating water pressure is between 1 and 2.0 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer. © Baxi Heating UK Ltd 2012...
  • Page 4: Troubleshooting

    ? If the reading falls below 1 bar repressurise the system as Turn the ON/OFF/Reset described in section 3.1. Selector Switch to Reset. If boiler does not Reset Error Code E119 showing low pressure. © Baxi Heating UK Ltd 2012...
  • Page 5 INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible. © Baxi Heating UK Ltd 2012...
  • Page 6: Repressurising System

    8. Disconnect the metal braided hose from the taps (a small amount of water may be present) and remove it. Keep the hose in a safe place for future use. © Baxi Heating UK Ltd 2012...
  • Page 7: Clearances

    11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 5mm Min Fig. 4 In Operation © Baxi Heating UK Ltd 2012...
  • Page 8: Care Of The Boiler

    5 Fan or Fan Wiring Fault E160 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer. © Baxi Heating UK Ltd 2012...
  • Page 9: Legislation

    The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The Benchmark Checklist may be required in the event of any warranty work. © Baxi Heating UK Ltd 2012...
  • Page 10: Notes

    7.0 Notes © Baxi Heating UK Ltd 2012...
  • Page 11: Emergency

    (Fig. 6). 3. Call your Installer or Service Engineer as soon as Fig. 6 possible. Heating Flow and Heating Return Inlet Isolating Valves © Baxi Heating UK Ltd 2012...
  • Page 12: Warranty & Service

    Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 013 7989.