Thermocouple - Baxi Solo 2 60 RS Installation And Servicing Instructions

Wall mounted room sealed gas fired central heating boilers
Table of Contents

Advertisement

Pilot Supply
Tube at Gas
Valve
Release nuts holding thermocouple in place. Bend
new thermocouple to required shape, fit in place and
tighten retaining nuts.
Caution: Do not overtighten nuts.

Thermocouple

at Gas Valve
Disconnect thermocouple, spark electrode and pilot
feed pipe from pilot bracket.
DO NOT remove pilot viewing window. Carefully
remove pilot injector.
Undo the four screws retaining the bracket to the
door and remove. Check pilot gasket and
replace if necessary.
Fit new pilot bracket. Reassemble in reverse order.
Thermocouple
Spark Electrode & Lead
Unclip the electrode from the pilot
bracket and remove lead from piezo
igniter. Replace with new spark
electrode ensuring it is fully engaged.
Pilot Injector
Disconnect nuts on pilot supply tube
and remove. Extract injector, using a
small screwdriver.
Fit new injector and reassemble.
Pilot Bracket & Gasket
35