Main Thermostat - Baxi Solo 2 60 RS Installation And Servicing Instructions

Wall mounted room sealed gas fired central heating boilers
Table of Contents

Advertisement

1
2
4
6
8

Main Thermostat

Loosen the screw on the capillary retaining washer,
allowing the washer to move freely. Free the
capillaries from the clips on the left hand side of the
combustion box. Withdraw both thermostat phials
from the thermostat pocket.
Disconnect the electrical plug and cable on the gas
valve.
Carefully pull off the thermostat knob. Loosen the
securing screw sufficiently for the electrical box cover
to be removed, remove cover.
Disconnect the wires of the input and pump outlet
3
cables from the terminal strips. Loosen the
screws on the cable clamps. Boilers
converted for use on gravity D.H.W. will
have wiring only to the left hand terminal
strip.
Remove the rear part of the thermostat box
by removing the screws at the side.
5
Release the locknut securing the main boiler
thermostat to the mounting plate.
from the rear of the thermostat, taking
note of their orientation.
Remove thermostat taking care not to
damage the PCB.
Fit the new thermostat to the mounting
plate and reconnect the spade
7
1
2
3
4
5
Unfasten the screws holding the
thermostat box to its bracket on
the boiler combustion box. The
thermostat box is now free of the
boiler.
6
7
8
Pull off the spade connectors
connectors to the appropriate
terminals.
Reassemble all
components in reverse
order. (See pages 24 and
25 for electrical
connections).
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solo 2 50 rsSolo 2 40 rsSolo 2 30 rs