Wall Enclosure Rough Opening - kozy heat BAYPORT-41 LOG BAY-41-L Installation And Operation Manual

Direct vent gas fireplace
Hide thumbs Also See for BAYPORT-41 LOG BAY-41-L:
Table of Contents

Advertisement

3.4 Wall Enclosure Rough Opening

WARNING: Provide adequate clearances around air openings
into the combustion chamber. Provide adequate clearance in
front of the fireplace for barrier removal, component access,
gas line installation, service access, etc.
Framing dimensions should allow for wall covering thickness
and fireplace facing materials. If using a hearth, adjust the
rough opening size as necessary to maintain minimum
clearance requirements.
Figure 3.3, Finished Opening Dimensions
If masonry is to be used (optional), prepare the necessary
foundation for the masonry load. When masonry construction
is to be used, a lintel must be used over the top of the
appliance to support the additional weight.
If installing the optional heat duct kit, refer to Section 4.0
#970 Heat Duct Kit on page 15.
44½"
(1130mm)
41 ⁄ "
(1051mm)
17½"
(445mm)
SINGLE VERTICAL HEADER
BOARD IS REQUIRED TO
MAINTAIN CLEARANCES TO
COMBUSTIBLES
FRAMING 13