Internal Signal Tab Window - Sony SRM-L560 Operating Instructions Manual

Lcd video monitor
Hide thumbs Also See for SRM-L560:
Table of Contents

Advertisement

Zebra Pattern: Sets the zebra pattern displayed in the
clipped portions.
Note
When the setting for the zebra pattern is changed, Zebra
Pattern of the Gamut Error Display tab window is also set
to the same setting value.
Line: Sets the direction of the pattern.
[Diagonal Type1]: Right descending
Diagonal Type2: Left descending
Modulation: Sets the amplitude of the pattern display.

Internal Signal Tab Window

This window is used to set the internal signal.
a Generate Internal Signal
Sets whether or not to display the internal signal (On or
[Off]).
Internal Signal Pattern: Sets the type of the internal
signal.
[PLUGE]: PLUGE signal
64
Display Function Window
Set to 1 to 50. [16]
b Force Sync Lock
Sets whether or not to enable the forced sync lock (On or
[Off]) when the display mode is 4K/QFHD.
When displaying in 4K/QFHD mode, all the input signals
from the inputs A to D should be genlocked to synchronize
with one another.
Normally set Force Sync Lock to Off. When the input
signals are not genlocked and the image is disturbed, set
Force Sync Lock to On. The disturbance of the image may
be decreased.
1
Gray: 20% gray signal
White: 100% white signal
5Step: 5 step gray scale signal
Ramp: Ramp signal
Color Bars: Color bar signal
Black: 0% black signal