Before automatic adjustment, select the value to use for the
adjustment in following sequence.
When you use the previously adjusted values for
adjustment, click Start Adjustment without performing
steps 1, 2 and 3.
1Select the color temperature to be used in Standard
Color Temp of Target Color.
When Any xy is selected, enter the values of the CIE color
system x and y coordinates.
2When Contrast Hold is set to Off, select Target
2
Luminance and enter the value of the luminance (cd/m
)
when the 100% white signal is input.
3Select the probe to be used in Probe.
4Click Start Adjustment.
When the probe is attached on the center of the display,
automatic adjustment starts and "In progress..." is
displayed during adjusting. (It may take some time until
the automatic adjustment is completed.)
Note
First connect the probe and then click Start Adjustment.
e Restore Factory Data
Resets the color temperature data to the default.
Color Temp
Confirmation. Restore Factory Data?
OK
Cancel
OK: Resets the setting to the default.
Cancel: Closes the window without resetting the setting.