Pf 63 And Pf 65 Control Panel Button Functions - Kemppi FastMig MXF 63 Operating Instructions Manual

Hide thumbs Also See for FastMig MXF 63:
Table of Contents

Advertisement

5.2

PF 63 and PF 65 control panel button functions

10.
EN
5.2.1 ON/OFF button
Short Press: Panel returns to default display.
Long Press: When welding panel (PF 65) is ON => Welding panel is turned OFF. When welding
panel (PF 65) OFF => welding panel is turned ON and Setup Panel (P65) turns ON and selects
automatically that welding panel (WF#).
5.2.2 Dynamics button
Short Press: Dynamics setting if welding process is MIG/Synergic MIG. ArcForce setting if
welding process is MMA. Forming Pulse setting if welding process is Wise-Root/WiseThin.
Long Press: Wire Feeder number selection (WF#). If more than one wire feeder is connected to
system WF number selection must be made. Every wire feeder must be different WF number.
5.2.3 Gas Test button
Gas Test function.
Pressing the button will show the gas test time. Gas test time can be adjusted by using the
pulse encoder.
Gas test will proceed after time adjustment is complete (short delay).
Gas test can be stopped by pressing any button.
(Gas test can also be started by pressing the Gas Test button inside the wire spool cabinet.)
20
FastMig MXF 63, 65, 67
1.
2.
3.
5. 6.
7.
1.
2.
3.
4.
11.
PF 65
8.
9.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig mxf 67Fastmig mxf 65

Table of Contents