Control Panel
Flash pattern
RX (Receive) Flashing
TX (Transmit) Flashing
Table 8.6: RX and TX LEDs descriptions
LINK (yellow) LED pattern
Flashing
Flashing
Table 8.7: Ethernet Link LEDs descriptions
8.4

B450 Conettix Plug-in Communicator Interface

The B450 Conettix Plug-in Communicator Interface gives the ability to connect more than one
cellular plug-in communicator to the control panel by providing an interface to the control
panel's SDI2 wiring.
The B450 supports one cellular plug-in module.
B450 Conettix Plug-in Communicator Interface connects to the SDI2 bus on the control panel
using terminals PWR, A, B, and COM, or using the SDI2 interconnect wiring connector. This
section includes basic installation instructions. For detailed installation instructions, refer to
the Conettix Plug-in Communicator Interface (B450) Installation and Operation Guide.
Bosch Security Systems, Inc.
100Mb (green) LED pattern
Off
On Steady
On Steady
Installation and System Reference Guide
Function
Occurs when the module receives a message over the
network connection – UPD, TCP, or DNS.
Occurs when the module sends a message over the
network connection – UPD, TCP, or DNS.
Off
Off
Off
On Steady
On Steady
IP communications | en
Function
No Ethernet link
10Base-T link
10Base-T activity
100Base-TX link
100Base-TX activity
2015.07 | 12 | F.01U.287.180