Control Panel
4.
5.
6.
B93x/B94x keypads configuration of IPv4 Subnet Mask
1.
2.
3.
4.
5.
6.
Default Gateway
B91x/B92x keypads configuration of Default Gateway
1.
2.
3.
4.
5.
6.
B93x/B94x keypads configuration of Default Gateway
1.
2.
3.
4.
5.
6.
HTTP Port Number
B91x/B92x keypads configuration of HTTP Port Number
1.
2.
3.
4.
5.
6.
Bosch Security Systems, Inc.
Delete the existing number, if necessary, and then enter the new number. Use [PREV] or
[NEXT] to move to a different byte.
Press [ENTER] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[2] Subnet Mask.
Press [IPv4 Subnet Mask] to edit the subnet mask address.
Delete the existing number, if necessary, and then enter the new number. Use
or
/[NEXT] to move to a different byte, and use the number keys to enter the new
numbers.
Press [Save] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[2] Address Parameters > [3] Default Gateway.
Press [ENTER] to edit the gateway.
Delete the existing number, if necessary, and then enter the new number. Use [PREV] or
[NEXT] to move to a different byte.
Press [ENTER] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[2] Address Parameters > [3] Default Gateway.
Press [Default Gateway] to edit the gateway.
Delete the existing number, if necessary, and then enter the new number. Use
or
/[NEXT] to move to a different byte.
Press [Save] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[2] Address Parameters > [4] HTTP Port Number.
Press [ENTER] to edit the port number.
Delete the existing number, if necessary, and then enter the new number.
Press [ENTER] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Installation and System Reference Guide
Keypad Installer menu | en
/[PREV]
/[PREV]
2015.07 | 12 | F.01U.287.180