Optional: Install The Backlighting Reflector; Install The Firebox Liners; Optional: Install The Backlighting Light Assemblies; Install The Glass Media - Superior DRL6542TEN Installation And Operation Instructions Manual

Drl 6000 series direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRL6000 Series Direct-Vent Gas Fireplaces
TM

Optional: Install the Backlighting Reflector

15.
See the kit literature for more information.

Install the Firebox Liners

16.
1. See Page 56 for instructions on Installing the Firebox Liners.

Optional: Install the Backlighting Light Assemblies

17.
See the kit literature for more information.

Install the Glass Media

18.
1. See Page 56 for instructions on Installing the Glass Media.

Install the Baffle

19.
1. With the baffle oriented as shown in Figure 38, slide the rear tabs into the slots in the back panel.
Figure 38: Baffle
2. While sliding the tabs into the slots, slide the front lip of the baffle under the clips in the firebox ceiling.

Install the Glass Door

20.
1. See Page 57 for instructions on Installing and removing the glass door.

Adjust the Air Shutter to Ensure Proper Flame Appearance

21.
• Air shutter adjustment should only be performed by a qualified professional service technician.
• Ensure glass door is in place and sealed during adjustment.
• Soot will be produced if the air shutter is closed too much. Any damage due to sooting,
resulting from improperly setting the air shutter, is not covered under the warranty.
• The air shutter rod and nearby appliance surfaces are hot. Exercise caution to avoid injury
while adjusting flame appearance.
Flame Appearance and Sooting
The flame should be blue at the base, and yellow-orange in the body of the flame.
When the fireplace is first lit, the entire flame may be blue and will gradually turn yellow-orange during the first 30
minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air
shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at
the tips of very long orange flames. Sooting results in black deposits forming on the fireplace inside surfaces and on
exterior surfaces adjacent to the vent termination.