2. Connect the flare fitting on the flex-line to the shutoff valve. Tighten by hand, and then use a pipe wrench to
Figure 35: Control Compartment
Access the Control Compartment
See Page 53 for instructions on Accessing the Control Compartment.
The control valve has a 3/8" (10 mm) NPT thread inlet port.
Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are
used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and
other openings can be caulked or stuffed with unfaced fiberglass insulation.
All codes require a shutoff valve mounted in the supply line. The orientation of the shutoff valve should face the
front. Figure 36 illustrates two methods for connecting the gas supply. A sediment trap is recommended to prevent
moisture and debris in the gas line from damaging the valve.
Test Factory and Field Connections for Gas Leaks
Never use an open flame to check for leaks.
Turn on gas supply and test for gas leaks, using a gas leak test solution—also known as bubble leak solution.
NOTE: Using a soapy water solution is an effective leak test solution but it is not recommended, because the soap
residue that is left on the pipes/fittings can result in corrosion over time.
1. Light the fireplace (refer to the lighting instructions label in the control compartment or Page 68).
2. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas
3. When the gas lines are tested and leak free, rinse off the leak testing solution.

Verify Proper Fireplace Operation

14.
1. With the gas line installed, inspect the system before closing the front of the unit.
2. Follow the pilot lighting instructions (Page 68).
3. To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame
Figure 37: Electronic Pilot
38
tighten completely, 1/4-turn at a time.
Main gas shutoff valve
odor is detected, turn the receiver or remote control to the OFF position. Either tighten or refasten the leaking
connection, and then retest as described above.
NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air.
When purged, the pilot and burner will light and operate as indicated. Subsequent lighting of the fireplace will not
require purging.
should engulf the flame rod (Figure 37).
Igniter
Flame
Rod
WARNING
Pilot Hood
Figure 36: Gas Line Connection
Flex Line Connector
1/2 x 3/8" Flare
3/8 NPT x 3/8"
3/8" NPT x 3/8"
1/2" x 3/8" Flare
shutoff valve
Flare Fitting
Flare fitting
Shut-Off Valve
Gas
Gas
Stub
stub
3/8" Flex tubing
3/8" Flex Tubing
Installation
900077-00, 03/2014
Gas
Gas
valve
Valve