Superior DRL6542TEN Installation And Operation Instructions Manual page 8

Drl 6000 series direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRL6000 Series Direct-Vent Gas Fireplaces
TM
Approved Vent Components
These fireplaces are designed, tested and listed for operation and installation with the following vent
components only:
Use only the correct size venting (4 1/2" inner and 7 1/2" outer).
These approved vent system components are labeled for identification. DO NOT use any other manufacturer's vent
components with these fireplaces.
Codes and Standards
These fireplaces comply with National Safety Standards and are tested and listed by Intertek (Report No.
100404899PRT-001) to ANSI Z21.88 (in Canada, CSA-2.33), and CAN/CGA-2.17-M91 (CSA P4.1) in both USA and
Canada, as vented gas fireplace heaters.
These fireplaces are listed for installation in bedrooms, aftermarket mobile homes, and manufactured homes.
The installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54—latest edition (In Canada, the current CAN/CGA-B149.1 installation code).
The fireplace, when installed, must be electrically grounded and wired in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70—latest edition, or the Canadian Electrical
Code, CSA C22.1—latest edition.
BTU Input
Table 1: Input Rate, Gas Valves
Table 2: Thermal Efficiency (%)
* AFUE is a measurement of the US Department of Energy
** P4 (EnerGuide) is a measurement of the Canadian Office of Energy Efficiency.
Gas Pressure
Table 3: Inlet Gas Supply Pressure
Table 4: Manifold Gas Supply Pressure
The control valves have a 3/8" (10 mm) NPT thread inlet and outlet side of the valve (Figure 1).
8
Secure Vent
Direct-Vent System Components,
®
Secure Flex
Flexible Vent Components, and
®
Z-FLEX
Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster
®
Canada Limited.
Models
Low
42"
High
Low
54"
High
Model
42"
54"
Fuel
Natural Gas
Propane
Fuel
Natural Gas
Propane
Input Rate (BTU/HR)
Natural Gas
19,500
27,000
26,000
37,000
Natural Gas
AFUE *
P4 **
67
61
70.2
66.9
Minimum
5" WC / (1.25 kPa)
11.0" WC / (2.74 kPa)
Low
1.6" WC / (0.4 kPa)
6.3" WC / (1.57 kPa)
Installation
900077-00, 03/2014
Propane (field converted)
19,500
25,000
27,000
34,000
Propane (field converted)
AFUE *
P4 **
68.5
66
69.8
71.8
Maximum
10.5" WC / (2.61 kPa)
13.0" WC / (3.23 kPa)
High
3.5" WC / (0.87 kPa)
10.0" WC / (2.49 kPa)