If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this
is the only gas appliance in the dwelling—see NPFA 58), there may be a loss of pressure.
This can result in insufficient fuel delivery that can cause sooting, delayed ignition, or other
malfunctions. Any damage resulting from an improper installation is not covered by the
limited warranty.
Rough in the Electrical Supply, if Needed
4.
1. As necessary, rough in the fireplace electrical supply per NEC and local codes.
Prepare the Fireplace Nailing Flanges
5.
NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are
EXEMPT from the 1/2" clearance to combustible requirements for the firebox outer wrapper. Combustible framing
may be in direct contact with the nailing flanges and may be located within 1/2" of screw heads and the firebox
wrapper in areas adjacent to the nailing flanges.
Nailing flange positions are provided for the following wall finish thicknesses:
NOTE: A second, field-supplied noncombustible board should be installed over the supplied noncombustible board.
The fireboard supplied with the unit is not intended to be the finish material. Consider this when calculating the total
wall finish thickness for nailing flange positioning.
Preparing the nailing flanges for a cleanface finish installation
1. If the wall finish material is thicker than 1/2", move the nailing flanges to the correct horizontal position.
NOTE: The nailing flanges are set at the factory in the correct vertical position for a cleanface installation (Figure 12).
Figure 12: Vertical nailing flange settings for cleanface finish
Preparing the nailing flanges for a surround/bezel finish installation
1. Move the nailing flanges to the correct vertical positions (Figure 13).
2. Adjust the nailing flanges to the correct horizontal position.
1/2"
3/4"
1"
1 1/4"
1 1/2"
CAUTION
Figure 13: Vertical nailing flange settings for surround/bezel finish