Superior DRT6345TEN Installation And Operation Instructions Manual

Superior DRT6345TEN Installation And Operation Instructions Manual

Superior drt/drc6300 series 40 and 45 in. direct vent gas fireplaces

Advertisement

P/N 900343-01 Rev. NC 01/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900343-03.
P900343-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
Superior DRT/DRC6300 Series 40 and 45 in. Direct
Vent Gas Fireplaces
PFS
Models
DRT6345TEN
®
DRT6345TEP
C
US
DRC6345TEN
Report No. F14-106
DRC6345TEP
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec
la vitre chaude et doit être installé pour la protection
Des enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
• Si vous ne pouvez rejoindre le fournisseur de
— L'installation et l'entretien doivent être assurés par
AVERTISSEMENT:
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
gaz depuis un voisin. Suivez les instructions du
fournisseur.
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRT6340TEN
DRT6340TEP
DRC6340TEN
DRC6340TEP

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRT6345TEN

  • Page 1 Installation and Operation Instructions Superior DRT/DRC6300 Series 40 and 45 in. Direct Vent Gas Fireplaces P/N 900343-01 Rev. NC 01/2015 Models Ce manuel est disponible en francais, simplement DRT6345TEN DRT6340TEN ® en faire la demande. Numéro de la pièce 900343-03.
  • Page 2 Innovative Hearth Products General Information Superior DRT/DRC6300 Series Direct-Vent Gas Fireplaces 900343-01 01/2015 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information 900343-00 01/2015 Superior DRT/DRC6300 Series Direct-Vent Gas Fireplaces Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la...
  • Page 4: Table Of Contents

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION Please read and understand these instructions before beginning your The DRT/DRC6300 Series direct-vent, sealed- Packaging ......4 installation.
  • Page 5: General Information

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS GENERAL INFORMATION Installation and repair should be done by WARNING a qualified service person. The appliance should be inspected before use and at least WARNING Improper installation, adjust- annually by a professional service person. More frequent cleaning may be required due ment, alteration, service or to excessive lint from carpeting, bedding ma-...
  • Page 6: Massachusetts Requirements

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS COMMONWEALTH OF MASSACHUSETTS Orifice Sizes—Sea Level To High Altitude These electronic appliances are remotely (All Models) REQUIREMENTS controlled and feature an electronic intermit- tent pilot ignition system or standing pilot. These appliances are tested and approved External electrical power is required to operate These appliances are approved for installation in...
  • Page 7: Cold Climate Insulation

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
  • Page 8: Vent Termination Clearances

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS VENT TERMINATION CLEARANCES These instructions should be used as a Vertical Vent Termination Clearances Termination Heights For Vents guideline and do not supersede local codes Above Flat Or Sloped Roofs in any way.
  • Page 9 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Inside Corner Outside Corner Recessed Location See Figure 4 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed Closed Openable TERMINATION CAP GAS METER RESTRICTED AREA AIR SUPPLY INLET (TERMINATION PROHIBITED)
  • Page 10: Minimum Clearances To Combustibles

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS MINIMUM CLEARANCES TO COMBUSTIBLES Combustible Shelf Height— Inches (millimeters) The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5), with the following exception: When Top Vent—with 2 Feet Vertical Vent and One 90 Degree Elbow the unit is installed with one side flush with a wall, the wall on the Model...
  • Page 11: Detailed Installation Steps

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 1. FRAMING TYPICAL INSTALLATION SEQUENCE WARNING Frame these appliances as illustrated in Figure The typical sequence of installation is outlined Failure to position the parts in 11 on Page 12, unless the appliance is to be below.
  • Page 12: Fireplace And Framing Specifications

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Framing Dimensions Model Framing should be constructed 50-3/4 75-1/8 40 in. VENT FRAMING of 2x4 or larger lumber. TOP VENT WITH 2 FEET 1289 1143 1908 Framing should be constructed VERTICAL VENT AND VENT FRAMING of 2x4 or larger lumber.
  • Page 13: Step 2. Routing Gas Line

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Model 50-5/8 83-5/8 59-1/8 41-7/8 40 in. 1286 2124 1502 1064 56-3/4 89-7/8 63-1/2 44-7/8 45 in. 1441 2283 1613 1140 Back wall of chase/enclosure (including any finishing materials) Figure 12—Corner Framing with Square Termination (SV8HTS) NOTES: Step 2.
  • Page 14: Step 3. Install The Vent System

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Select Venting System—Horizontal or Vertical Step 3. INSTALL THE VENT SYSTEM Installation of Vent Restrictor A vent restrictor may be needed with this General Information With the appliance secured in framing, de- appliance.
  • Page 15: Vertical Termination Systems

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS VERTICAL TERMINATION SYSTEMS (ROOF) i t c i t c See Figure 15 and Figures 23 through 25 on i t c i t c Page 18 and their associated Vertical Vent o i t Tables which illustrate the various vertical venting configurations that are possible for use with these...
  • Page 16 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS B. Attach vent components to appliance—Se- Push the vent component against the previous Vertical (Offset) Installation cure Vent SV8 direct-vent system components section until it fully engages, then twist the ®...
  • Page 17 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS One method of support is by utilizing field pro- K. Install the vertical termination—The final vided support straps (conventional plumber's step involves installation of the Vertical Termina- tape). Secure the plumber's tape to the framing tion.
  • Page 18: Vertical Vent Tables And Figures

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS VERTICAL VENT FIGURES/TABLES Table A NOTES: • Secure Vent (rigid vent pipe) is shown in V Minimum ® H Maximum the figures. feet (meter) feet (meter) • It is very important that the horizontal/ inclined run be maintained in a straight (3.1) (0.762)
  • Page 19: Horizontal Termination System

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS HORIZONTAL (OUTSIDE WALL) TERMINATION Support Horizontal / Inclined Run SV8HTS Building SYSTEM Brackets Termination Support Shown Framing See Figures 26–31 and their associated Horizontal Vent tables that illustrate the vari- SV8E90 Elbow ous horizontal venting configurations that are...
  • Page 20 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS J. Assemble vent run to exterior wall—If not To help minimize water infiltration it SV8HTS previously measured, locate the center of the is recommended that the Firestop/ Termination To help minimize water infiltration vent at the exterior wall.
  • Page 21: Horizontal Vent Tables And Figures

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS HORIZONTAL VENT FIGURES/TABLES See Table 9 as an aid in venting component selection for a particular range of exterior wall thicknesses. NOTES: Venting Components Required for Various Exterior • Secure Vent components (rigid vent pipe and terminal) are shown ®...
  • Page 22 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS HORIZONTAL VENT FIGURES/TABLES (continued) Wall Firestop/Spacer Table D (SV8HF) V Minimum Maximum feet (meter) feet (meter) (1.07) (0.762) (1.98) (1.07) (2.6) (1.37) 10.5 (3.2) (1.68) 12.5 (3.8) (1.98) Wall Firestop/Spacer 14.5 (4.4) (2.3)
  • Page 23: Step 4. Field Wiring

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 4. FIELD WIRING Verify proper operation after servicing. 6. Install the wall-mounted ON/OFF control, as described in "Installing and initializing the S’assurer que l’appareil fonctionne Remote Control System" on Page 24, in a adéquatement une fois l’entretien CAUTION convenient location near the fireplace.
  • Page 24 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS The remote control system provides remote Installing and initializing the Remote WARNING operation of the following fireplace functions: Control System • Primary burner ON/OFF Fire hazard. Can cause severe REQUIRED ITEMS (not provided): •...
  • Page 25: Step 5. Removing Glass Door Frame Assembly

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 5. REMOVE GLASS DOOR FRAME A. Light the appliance (refer to the lighting instructions label in the control compartment Right Side Remove the glass door assembly. See Installa- or in the Care and Operation Instructions Modesty Panel tion and Removal of Glass Door on Page 28.
  • Page 26: Step 8. Installing Logs And Panels

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 8. INSTALL VOLCANIC STONE, GLOWING EMBERS, AND Step 4. Position the individual logs as shown in Figures 42 through 46. Logs should be placed in the order shown. Place logs 2 and 3 LOGS (Traditional Only), or against the pins on the grate, NOT over them.
  • Page 27 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Traditional Only: Log Placement Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate. Figure 44 - Placing Logs 3 and 4 Log Number Description Log, Center...
  • Page 28: Step 9. Installing Glass Door

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 9. INSTALLATION AND REMOVAL Installing Glass Enclosure Panel Top Flange Glass door Glass Door Latch (2) (see Figure 47) OF GLASS DOOR assembly Retrieve the glass door. Visually inspect the WARNING gasket on the backside of the frame.
  • Page 29 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Air Shutter Adjustment Guidelines Use the remote to adjust the flame height as desired. • If there is smoke or soot present, first check Air Shutter the log set positioning to ensure that the Propane models may exhibit a flame pattern Opening that may candle or appear stringy.
  • Page 30: Finishing Requirements

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS FINISHING REQUIREMENTS Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with the exceptions. Wall Details Vertical installation clearances to combustible mantels vary according Complete finished interior wall.
  • Page 31: Step 11. Attaching Safety-In-Operation Warnings

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 11. INSTALLER INSTRUCTIONS—ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 32: Installation Accessories

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS INSTALLATION ACCESSORIES Listed Secure Vent Components H2262 SV8SU Support Strap ® Cat. Model Description H2266 SV8HTS Horizontal Square Termination with Firestop/Spacer H2263 SV8SP Support Plate (H2260) and Adaptor (H2267) H3908 SV8ARSA Attic Insulation...
  • Page 33: Gas Conversion Kits

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS GAS CONVERSION KITS Step 1. TURN OFF THE GAS SUPPLY TO THE APPLIANCE and disconnect power supply at the circuit breaker. Ensure appliance is cold. WARNING CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE This conversion kit shall be installed by a qualified service agency in ELECTRICAL POWER, BEFORE PROCEEDING...
  • Page 34: Operation And Care Of Your Appliance

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Step 6. Refer to the instructions provided Burner Orifice Sizes with the SIT regulator conversion kit. Using a Elevation 0-4500 feet ( 0-1372 meters) Pilot Torx T20 (with 1/4" shank and center hole) or Hood Natural Gas Propane...
  • Page 35: Important Safety Information

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS Important Safety Information L’information de sûreté importante 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en 1. WARNING: Do not operate appliance with the glass front verre n’est pas en place, est craqué...
  • Page 36 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS HOMEOWNER’S INSTRUCTIONS—ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD WARNINGS À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Votre foyer a été...
  • Page 37 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS APPLIANCE INSTALLATION, SERVICE, Turn off gas and electrical power to the WARRANTY INFORMATION fireplace and allow it to cool before AND MAINTENANCE NOTICES Your gas appliance is covered by a limited cleaning or servicing the appliance.
  • Page 38 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS BTU INPUT In Canada—CAN/CGA-2.17-M91 (R2009) The appliance and its appliance main gas (high altitude): valve must be disconnected from the gas The BTU Input for these appliances are shown supply piping system during any pressure THE CONVERSION SHALL BE CARRIED in Table 12.
  • Page 39 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS OPERATION AND CARE OF YOUR APPLIANCE Right Side WARNING Modesty Panel Access Plate Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns.
  • Page 40: Maintenance

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS MAINTENANCE The viewing glass should be cleaned periodi- NOTE: If installing the Contemporary Burner/ cally to remove any build-up caused from the Floor Kit, skip this step and instead refer to the instructions provided with the kit.
  • Page 41: Front Glass Enclosure Panel, Removal And Installation

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS FRONT GLASS ENCLOSURE PANEL, 3. Swing the door up and back. Ensure the WARNING REMOVAL AND INSTALLATION gasket seats evenly as the door draws shut. Engage the nut insert and fasten with two Any safety screen or guard screws to secure the door.
  • Page 42: Log, Volcanic Stone, And Glowing Ember Placemen

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS INSTALL VOLCANIC STONE, GLOWING EMBERS, AND 4. Position the individual logs as shown in Figure 7 through Figure 11 LOGS (TRADITIONAL ONLY), OR on Page 11. Logs should be placed in the order shown. Place logs 2 GLASS MEDIA (CONTEMPORARY ONLY) and 3 against the pins on the grate, NOT over them.
  • Page 43 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS Traditional Only: Log Placement Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate. Figure 68 - Placing Logs 3 and 4 Log Number Description Log, Center...
  • Page 44: Burner Adjustments

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS BURNER ADJUSTMENTS Contemporary Media Shown (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame.
  • Page 45: Burner Air Shutter Adjustment

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS BURNER FLAME ADJUSTMENTS Electronic Appliance Checkout (QUALIFIED TECHNICIANS ONLY) Air Shutter To light the burner, turn on the remote control. Opening Ensure the igniter lights the pilot. The pilot WARNING flame should engulf the flame rod as shown in Figure 74.
  • Page 46: Ordering Replacement Parts

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS ORDERING REPLACEMENT PARTS When ordering repair parts always provide: PRODUCT REFERENCE INFORMATION 1. The model number of the appliance. A complete parts list is found at the end of We recommend that you record the important 2.
  • Page 47 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS ACCESSORY COMPONENTS Bag of Glowing Embers Bag of Volcanic Stone Touch-Up Paint Kit Bag of Platinum Embers Repair of minor scratches and discoloration of the appliances black painted surfaces may be accom- Replacement ember material, volcanic stone and Firebox Liner Kits plished with the touch-up paint kit.
  • Page 48 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS Dual Arch Screen Kits Arch Screen Kits Mission Classic These Dual Arch screen kits can be placed in front These Arch Screen kits can be placed in front of the Andiron Grate Kits of the glass enclosure panel to help prevent direct glass enclosure panel to help prevent direct human...
  • Page 49: Lighting Instructions

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. •...
  • Page 50 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 51: Maintenance Schedule

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS MAINTENANCE SCHEDULE Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE...
  • Page 52: Troubleshooting Guide

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS TROUBLESHOOTING GUIDE NOTE: Before troubleshooting, be sure that the appliance main line gas shut-off valve and the wall switch are in the “ON” position. The following troubleshoots the fireplace only to an elementary level. For detailed Remote and Ignition System troubleshooting, refer to the instructions provided with the remote.
  • Page 53: Replacement Parts List

    INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS REPLACEMENT PARTS LIST 40 in. 45 in. Gas Controls—SIT Electronic Item Description Cat. Natural Gas Propane Gas Qty. Cat. No. Qty. Item Description Part Qty. Part No. Qty.
  • Page 54 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • CARE AND OPERATION INSTRUCTIONS REPLACEMENT PARTS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 55: Year Limited Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 56 INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACES (DRT6300/DRC6300) • INSTALLATION INSTRUCTIONS Contact an IHP dealer to obtain any of these parts. Please contact IHP for the phone number of your nearest IHP dealer. SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed...

Table of Contents