Superior DRI3030TEN Installation And Operation Manual

Direct-vent fireplace insert
Hide thumbs Also See for DRI3030TEN:

Advertisement

P/N 900125-01 REV. NC 01/2014
Ce manuel d'installation est disponible en
francais, s implement en faire la demande.
Numéro de la pièce 900185-01.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Report # 100501897PRT-001
P900125-01
AVERTISSEMENT

INSTALLATION AND OPERATION

Direct-Vent
Fireplace Insert
MODELS
DRI3030TEN
This fireplace insert is factory equipped for 40,000 BTU input and can be converted to
33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas or
P/N H5925 for Propane Gas).
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d'incindie ou d'explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
DRI2530TEN

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRI3030TEN

  • Page 1: Installation And Operation

    Direct-Vent Fireplace Insert P/N 900125-01 REV. NC 01/2014 MODELS Ce manuel d’installation est disponible en DRI3030TEN DRI2530TEN francais, s implement en faire la demande. Report # 100501897PRT-001 Numéro de la pièce 900185-01. This fireplace insert is factory equipped for 40,000 BTU input and can be converted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas or P/N H5925 for Propane Gas).
  • Page 2: Table Of Contents

    Troubleshooting ..........28 Clearances to Combustibles ........10 Replacement Parts ............ 29-30 Insert Leveling ............ 10 Accessories ............. 31-32 Fan Control Module Switch (DRI3030TEN model only) ..11 Insert Labels ............33-35 Installation .............. 11-17 Warranty ..............37 Venting Installation ..........11 Product Reference Information ..........
  • Page 3: Safety And Warning Information

    IMPORTANT SAFETY AND WARNING AVERTISSEMENT INFORMATION On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité. WARNING WARNING Young children should be carefully supervised when they are in the same room as the appliance. Tod- Any safety screen or guard removed for servicing dlers, young children and others may be susceptible the appliance must be replaced prior to operating...
  • Page 4  T hese appliances are vented gas appliances. Do not burn wood  F OR YOUR SAFETY do not install or operate this appliance without or other material in these appliances. first reading and understanding this manual. Any installation or operation of the appliance deviating from that which is stated  T his appliance is only for use with the type of gas indicated on in this manual WILL void the warranty and may be hazardous.
  • Page 5: Homeowner - Attaching Safety In Operation Warnings

    ATTACHING SAFETY-IN-OPERATION WARNING LABELS ATTACHING SAFETY IN OPERATION WARNINGS COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD APPOSITION DES MISES EN GARDE RELATIVES EN OPERACIóN à LA SéCURITé D’UTILISATION It is required that the set of safety instruction labels that have been furnished with the appliance be affixed Se requiere que el juego de etiquetas de instrucciones Il est impératif que le jeu d’étiquettes de sécurité...
  • Page 6: Orifice Size/Altitude Adjustment

    IMPORTANT: When installing these appliances into a factory ORIFICE SIZE/ALTITUDE ADJUSTMENT built fireplace or heat-form, the air flow within and around the fireplace shall not be altered by the installation of the insert For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice (i.e.
  • Page 7: Codes And Approvals

    CODES AND APPROVALS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS (Massachusetts Approval #G3-1104-102) Certification These appliances are approved for installation in the US state of Mas- Gas appliances must be tested and certified by a nationally recognized sachusetts if the following additional requirements are met: testing and certification laboratory to ANSI (American National Standard Institute) gas appliance safety standards.
  • Page 8: Pre-Installation

    Only IHP conversion kits can be Zen Garden used to convert from NG to LP or LP to NG. Contact your IHP dealer for details. RATINGS DRI3030TEN-40 / DRI2530TEN-40 DRI3030TEN-33 / DRI2530TEN-33 NATURAL GAS LP GAS NATURAL GAS...
  • Page 9: Insert And Fireplace Dimensions

    31-1/4" 31-1/8 (794mm) O.D. = 2-15/16" (75mm) 15-7/8" 15-7/8 13-3/8" (403mm) 13-3/8 (340mm) Top View 15-7/8" 15-7/8 (403mm) 19-3/8" 19-3/8 (492mm) Right Side View Front View Left Side View Figure 2 - Insert Dimensions Minimum Fireplace Opening 31-1/2" (800mm) Front Opening Width 19-1/2”...
  • Page 10: Clearances To Combustibles

    Facing and Mantel Clearances 800mm 927mm Please note that the DRI3030TEN-33 and DRI2530TEN-33 mantel clear- ances are 4" less than the DRI3030TEN-40 and DRI2530TEN-40 mantel clearances as shown in Figure 4A - DRI3030TEN-40 and DRI2530TEN-40 and Figure 4B - DRI3030TEN-33 DRI2530TEN-33. Figure 4B...
  • Page 11: Fan Control Module Switch (Dri3030Ten Model Only)

    FAN CONTROL MODULE SWITCH INSTALLATION DRI3030TEN-33 and DRI3030TEN-40 Models Only Venting Installation Before installation, verify the power switch on the Fan Control Module is in the ON position (as shown in Figure 6). Your IHP appliance must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In Canada, the...
  • Page 12 Vertical Venting The existing fireplace chimneys The vent pipes must be connected to the proper collars on the unit and may take various contours the exhaust vent pipe must be connected to the termination cap or the which the flexible liners will unit will not operate.
  • Page 13: Zero Clearance Fireplace Installation

    5. Reinstall burner by completing Step 3 in reverse. 6. Reinstall log rack by completing Step 2 in reverse. 7. The foil sticker supplied, stating DRI3030TEN-33 or DRI2530TEN-33, Rear Log Log Rack will need to be affixed below the model name on the serial number label (located in the control compartment).
  • Page 14: Surround Panels Installation

    Top Log Figure 13 Ports Surround Installation The fireplace insert surround panels are made of heavy gage steel for durability and, if desired, for the ease of making an inside fit in the fire- Figure 10 Side Firebox Panels place. See Packaging List for available sizes. 1.
  • Page 15: Operating Options

    - DRI2530TEN Models Only Operating Options OPTION 1 Burner ON/OFF Switch Installation: Surround The burner ON/OFF switch on your gas appliance is used to turn the burner Panel on and off. This switch can be installed in the hole in the right side of the top surround panel (see Option 1) or in the hole in the control panel in the control compartment (see Option 2).
  • Page 16: Gas Line Installation

    Cover the tap with the line from DRI3030TEN Models a manometer and check the pressure. Close the tap gently but securely Stepper Motor Green Wire after completing the check.
  • Page 17: Air Shutter Adjustment

    BL OW ER OF F DRI2530TEN Battery Holder See Shutter Adjustment Figure 19a Detail (Figure 19b) BU RN ER DRI3030TEN TO TA L AU TO CO MF OR CO NT RO PIL OT 5/32” Air Shutter Setscrew Battery Holder Ensure Positive and Negative...
  • Page 18: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACH SAFETY-IN- A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. OPERATION WARNING LABELS B. BEFORE OPERATING smell all around the appliance area for gas. Be sure It is required that the set of safety instruction labels that have to smell next to the floor because some gas is heavier than air and will been furnished with the appliance be affixed to the operation...
  • Page 19 Electronic Gas Control Valve SIT Proflame, Stepper BU RN ER TO TA L C O M FO C O N TR AU TO PI LO T Unit-Mounted Controls Figure 21B - DRI3030TEN Models NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 20: Operation - Model Dri3030Ten Only

    OPERATION - DRI3030TEN Model Only Receiver Remote Control System REMOTE OFF The Remote and Receiver allows you to command the functions of your appliance from the comfort of your chair and is configured to control the On/Off primary burner operation, its flame levels (through six levels) and provides On/Off and Smart thermostatic control of the appliance.
  • Page 21 OPERATION - DRI3030TEN Model Only Child Safety Lock-Out Transmission Low Battery Alarm Temperature Indicator Display Thermostat With the system in the “OFF” position, press the Thermostat Key and Room Temperature Off/On/Smart the Mode Key at the same time (see Figure 23). Look at the LCD screen...
  • Page 22: Flame Color And Behavior

    3. Once the blower turns on, turn the knob (DRI2530TEN) or adjust Adjust the primary air shutter(s) as required. Check for proper main the remote control (DRI3030TEN) to the desired speed. No further burner operation at both high and low flame.
  • Page 23: Wiring Diagrams

    120 V AC POWER OUTLET ROOM AIR BLOWER AC/DC ADAPTER BURNER PILOT CONTROL NOTE: SWITCH CONDITIONS BOARD GIVEN AT ROOM TEMPERATURE N/C = NORMALLY CLOSED 3-BLK N/O = NORMALLY OPEN = FEMALE DISCONNECT 9 - YLW = MALE DISCONNECT VALVE 8 - GRN 2 - RED = STUD CONNECTION...
  • Page 24 N/C = NORMALLY CLOSED N/O = NORMALLY OPEN = FEMALE DISCONNECT Figure 28C - Electronic Control Schematic - Model DRI3030TEN = MALE DISCONNECT = STUD CONNECTION CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 25: Maintenance And Servicing

    o Check that the area around the insert is kept clear and is free of MAINTENANCE AND SERVICING combustible materials, gasoline and other flammable vapors and liquids. WARNING 2. The viewing glass should be cleaned periodically (see Glass Main- tenance). Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 26: Door Removal

    Glass Door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame. •...
  • Page 27: Fuel Conversion

    Fuel Conversion See Detail B Converting this appliance between natural gas and propane (LP) can be accomplished by installing a gas conversion kit. Only a qualified service technician should perform the conversion. Gas Conversion Kits: Please see instructions provided with conversion kit.
  • Page 28: Troubleshooting

    Check/replace back-up batteries (see Battery Backup on Page 17). ing power. Check building circuit breakers to ensure power is on to the appliance. DRI3030TEN Models: Check Fan Control Module power switch to ensure power is on (see Figure 6 on Page 11). The main burner does Gas is not reaching the Check the gas supply and gas shutoff valves.
  • Page 29 H8456 Gas Conversion Kit, Manual Hi/Lo Regulator, LP H8505 DRI3030TEN Control Panel to NG H8482 Heat Shield, Fan Control Module - For DRI3030TEN H8457 Gas Conversion Kit, Manual Hi/Lo Regulator, NG Models Only to LP H8483 Blower Snap Switch, 160°-20°F...
  • Page 30 REPLACEMENT PARTS - DRI3030TEN AND DRI2530TEN NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 31: Accessories

    ACCESSORIES - DRI3030TEN AND DRI2530TEN DRI3030TEN-33 DRI2530TEN-33 Product Reference Information Gas Conversion Kits Cat. No. Description Ship. Ship. Weight Volume F1788 DRI3030TEN 144 lb. 16.9 cu. ft. F1787 DRI2530TEN 144 lb. 16.9 cu. ft. Cat. No. Model Description H8456 RDV-CK-HILO-LP to NG...
  • Page 32 H5144 GFT3341-B Trim/Black 33" x 41" H5146 GFT3348-B Trim/Black 33" x 48" 75036 GFT2941-G Trim/Gold 29" x 41" F1845 DRI3030TEN-CONTF-BLK Contemporary Face - Black 75038 GFT2948-G Trim/Gold 29" x 48" F1846 DRI3030TEN-CONTF-MNK Contemporary Face - Mink 75040 GFT3341-G Trim/Gold 33" x 41"...
  • Page 33: Insert Labels

    SAFETY / LISTING LABEL - DRI2530TEN SERIAL SERIAL Le numéro de série est indiqué dans la MODÈLE MODEL Ravenna™ IPI Ravenna™ IPI RDV IPI section anglophone de cette étiquette FABRIQUÉ PAR: MANUFACTURED BY: LENNOX HEARTH PRODUCTS Innovative Hearth Products LLC LENNOX HEARTH PRODUCTS Innovative Hearth Products LLC 1502 14TH ST NW...
  • Page 34 SAFETY / LISTING LABEL - DRI3030TEN SERIAL SERIAL Le numéro de série est indiqué dans la MODÈLE Ravenna™ TCC MODEL Ravenna™ TCC RDV TCC section anglophone de cette étiquette FABRIQUÉ PAR: MANUFACTURED BY: Innovative Hearth Products LLC LENNOX HEARTH PRODUCTS...
  • Page 35 LIGHTING LABEL POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE FOR YOUR SAFETY READ BEFORE OPERATING AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la WARNING: If you do not follow these instructions exactly, a fire or explosion may présente notice risque de déclencher un incendie ou une explosion entraînant des result causing property damage, personal injury or loss of life.
  • Page 36 NOTES...
  • Page 37: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 38: Replacement Parts

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your gas appliance is covered by a limited warranty (provided with When ordering repair parts, always give the following information: appliance).

This manual is also suitable for:

Dri2530ten

Table of Contents